Electrical fires consistently rank among the leading causes of commercial and residential fires, often resulting in death, injury, and significant property loss to businesses. Yet, many electrical fires can be prevented or easily contained through proper installation and maintenance of fixtures, location of equipment, training for employees, and greater awareness overall of the potential hazards of working with or near electricity. This article is intended to help businesses identify potential electrical hazards and discuss the necessary steps to take to reduce the likelihood of an electrical fire and potential resulting loss. Specific product standards and safety procedures relating to these points are set forth in various federal and state requirements stemming from the Occupational Safety and Health Act of 1970 (OSHA) and the National Electrical Code, which was developed by the National Fire Protection Association (NFPA).
Electricity for commercial buildings typically enters through an electrical distribution system, which varies in size and complexity depending on the business’s operations. An electrical distribution system is typically comprised of a network of circuits, including wiring, circuit breakers, fuses, and possibly additional step-down transformers for lower voltage equipment. Transformers in the electrical distribution system will pull power from the main local power grid and reduce the level of necessary power and distribute it throughout the
electrical distribution system in the building.
Electrical distribution systems are comprised of many complex components that can expose a commercial building to fire risks. Specific areas of concern include:
“Infrared thermal imaging” using a hand-held thermal scanner pointed at the electrical panel is an effective way to identify hot spots before they cause an electrical breakdown that can result in a fire. Smaller businesses may hire a licensed electrician to perform the inspection and provide a report and photos of the panels, while larger businesses may consider purchasing their own thermal scanner and training one or more employees on how to use the scanner and interpret the results.
Electrical distribution equipment should be periodically thermally imaged as well as physically inspected, cleaned, and tested by a licensed professional. Electrical distribution equipment to be inspected should include, at a minimum, the following:
Good housekeeping greatly reduces the odds for a fire. When electrical distribution equipment is in a separate dedicated room, the room should be temperature-controlled, well ventilated, clean, and dry to prevent moisture and excessive room temperatures that can degrade electrical materials. Additionally, keeping the room properly sealed will keep it free of dirt, dust, rodents, and pesky bugs that can get into the cabinets and degrade the equipment and potentially start a fire.
It is also important to keep combustible material away from electrical distribution systems, even if the room has an overhead sprinkler system. Too often, electrical rooms become a storage area for excess inventory or supplies, such as boxes, packaging materials, or janitorial supplies. It is important to note that direct contact with an electrical current is not the only way fires start. Electricity also can arc or jump through the air as a path to the ground and ignite combustible material in the vicinity. A carbon dioxide fire extinguisher is the proper method for extinguishing an electrical fire, however the best advice is to call the fire department and evacuate the building. If a dedicated electrical room is not available, electrical distribution panels or equipment may be located on a wall in a shared space. In these situations, combustible material should not be permitted within three feet of the equipment. Placing a yellow or red line on the floor is a simple way to remind and warn employees and visitors to keep their distance and not place combustible materials in this area. If distribution panels are located in an area where there may be moving vehicles such as forklift trucks or personnel carts, the equipment should be blocked by posts so it cannot accidentally be struck.
Any time electrical equipment is being repaired, removed, or replaced, proper safety procedures for electrical equipment systems, motors or other equipment should ALWAYS be implemented in order to prevent accidental reenergizing that could result in injury. Locking out and tagging electrical switchgear – placing a strictly controlled lock and tag on the main circuit breaker or disconnect switch controlling the disengaged equipment – should always be implemented when disabling electrical machinery of any kind. OSHA has specific lockout/tagout standard operating procedures including “The Control of Hazardous Energy (Lockout/Tagout),” Title 29 Code of Federal Regulations (CFR) Part 1910.147. In addition, 29 CFR 1910.333 provides requirements to protect employees working on electric circuits and equipment.
An often overlooked and common source for electrical fires is in lighting systems. When installing or replacing light bulbs or light fixtures, it is always recommended to use the wattage specified on the socket. In addition, fixtures should be placed away from high traffic areas where bulbs may be broken, and away from combustible materials. Unprotected light bulbs can be hit and broken, and may create sparks potentially causing a fire. Light bulbs can be protected by a simple plastic bulb cage. For large combustible storage, flammable liquids, or potentially explosive areas, explosion-proof lights are a prudent investment.
Additionally, it is important to look for visible signs of underlying fire hazards. Contact a qualified licensed electrician for an electrical system inspection if the following indicators are observed: Flickering or dimming lights may indicate a short in the wiring, dangerous arcing, or an over-extension of electrical systems. Multiple dimmed lights can also be a symptom of an overloaded circuit.
Periodic inspection and maintenance of electrical equipment can prevent breakdowns of vital power sources that control and light nearly all businesses. Employee safety, training, and knowledge of electrical equipment can ensure worker safety and prevent fires and other losses that can cause significant property damage and interrupt business operations. Additionally, as part of an established written electrical safety program, OSHA lockout/tagout standard operating procedures should be consistently followed by employees and contractors to help ensure personnel safety. Taking care of your equipment and employees is not expensive or complicated, but, over the long term, it is vital for keeping the lights on and your facility open for business.
©2024 SafePoint Insurance. All Rights Reserved.
Terms of Service • Privacy Statement • SMS Terms of Service